2.2.3/ Output format for 40 column printer: for small printers with a paper width of approx. 80 to 120mm.
Printing time per line may be entered, as small printers often have a limited input buffer
As for the 80 col. Printer, a header can be added at the start of the printing process. This is carried out as described in
the previous section. A new printout of the header can be activated by pressing the PRINT key for two seconds.
a/ printing example in normal measurement mode with tolerances activated and complete header:
b/ printing example in scanning mode with activated tolerances (incomplete header):
SYLVAC SA
Piece ident. : SHAFT
Date : 12/11/1998 Time : 14:49
CHANNEL MEAS.VALUE DEVIATION OUT OF TOL =
PIECE 1 : WORK
1 8.385 0.035 0.015 E>
2 5.098 -0.002 E=
3 12.235 0.015 I=
4 7.010 0.010 E=
SYLVAC SA
Piece ident. : SHAFT
Drawing nbr : PM230.010.412
Work station : L 201
Date : 12/11/1998 Time : 14:45
CHANNEL MEAS.VALUE DEVIATION OUT OF TOL =
1+ 2 13.421 5.071 5.051 E>
1+ 2 13.369 5.019 4.999 E>
1+ 2 13.405 5.055 5.035 E>
1+ 2 13.393 5.043 5.023 E>