750 50 0001 03 1/28 Dear customer, congratulations for your choice, a Trimos measuring instrument. Over more than 30 years, our products have b
750 50 0001 03 10/28 5 Basic functions 5.1 Selection of surface / diameter and centerline distance measurements To select the functions of surface
750 50 0001 03 11/28 5.3 Diameter and centerline distance measurements 1. Set the display at zero or at a preset value on a reference surface (see
750 50 0001 03 12/28 6 Secondary functions 6.1 References 6.1.1 Selection of references 4 references are available on the display unit. The activat
750 50 0001 03 13/28 6.5 Measuring in Min / Max / Delta mode The measurements in mode Min, Max Delta have always to be done with the probe being in
750 50 0001 03 14/28 3. After the measuring insert has been removed, the flatness value (Delta = maximum - minimum) will be stored and displayed i
750 50 0001 03 15/28 3. Connect the electronic probe to the display unit. 4. Activate the corresponding mode by pressing the key. The value of
750 50 0001 03 16/28 6.8 Angle measurements This function allows to measure an angle in relation to a reference surface (measuring plate). To perfor
750 50 0001 03 17/28 6.9 Difference between 2 measurements The Calc mode allows to calculate the distance between the last 2 surface or centerline
750 50 0001 03 18/28 3. To activate a tolerance input mode, press the Enter key. The fields at the right side of the symbol will than be activated.
750 50 0001 03 19/28 7 Programmable function keys The operating handle of the instrument includes one key to activate the air cushion displacement
750 50 0001 03 2/28 Contents 1 Safety regulations...
750 50 0001 03 20/28 Page 2 5. Date: y: year (4 numbers). m: month d: day 6. Time: h: hours min: minutes s: seconds 7. Contrast / luminous power
750 50 0001 03 21/28 9 Data communication 9.1 Data transfer All parameters for the data communication with the instrument are defined in the Print
750 50 0001 03 22/28 10 Application and adjustments 10.1 Application of the manual and the motorized handwheel Manual handwheel The manual handwhe
750 50 0001 03 23/28 Symbols for measuring modes / Buffer All measurements stored and displayed in the buffer have a 3 letter designation (measuring
750 50 0001 03 24/28 Level of battery charge: The level of the battery charge is indicated by a symbol: 1. 100% available power capacity 2. 75% av
750 50 0001 03 25/28 10.8 Adjustment of the measuring force 1. The instrument is supplied with a standard measuring setting of 1 N. The measuring
750 50 0001 03 26/28 10.10 Position of the measuring insert in the holder Be careful about the position of the measuring insert in the holder. The
750 50 0001 03 27/28 10.12 Temperature variations Temperature variations can significantly influence the measuring results. To reduce this influenc
750 50 0001 03 28/28 14 Declaration of conformity DECLARATION DE CONFORMITE KONFORMITÄTSERKLÄRUNG DECLARATION OF CONFORMITY TRIMOS déclare
750 50 0001 03 3/28 1 Safety regulations 1.1 Important information In order to prevent any damages due to a wrong manipulation, please read carefu
750 50 0001 03 4/28 2 Instrument description 2.2 15 17 16 9 10 8 6 5 4 3 2 1 7 13 2.1 14
750 50 0001 03 5/28 2.1 Instrument construction 1. Column 2. Upper measuring insert holder 3. Screw for the adjustment of the floating probe susp
750 50 0001 03 6/28 3 Getting started 3.1 Packing list The standard supply of the instrument includes the following items: 1. Instrument 2. Display
750 50 0001 03 7/28 3.2 Setting up After unpacking, prepare the instrument as follows : 1. Clean the air cushion pads positioned underneath the bas
750 50 0001 03 8/28 6. Slide the measuring insert into the holder (1) and lock it using the knob (2). 7. Release the transport safety screw (chro
750 50 0001 03 9/28 4 Getting started 4.1 Setting into operation The section § 10 will give you detailed information. 1. To switch on the instrume